| PID |
https://doi.org/10.48597/5KFW-VP5P |
| Revision |
1 |
| Revision date |
2025-02-15 00:00:00 |
| Revision description |
initial revision, manually inspected |
| Acknowledgements |
Request acknowledgement details from data originator |
| Importer |
yong |
| File |
FR0020R.20230101000000.20250215000000.chemiluminescence_photolytic.NOx.air.1y.1h.FR01L_Teledyne_T200UP.FR01L_NOx_analysis.lev3a.nas |
| Remarks |
SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol converted by TC from FR0020R.20230101000000.20240530133840.chemiluminescence_photolytic.NOx.air.1y.1mn.FR01L_Teledyne_T200UP.FR01L_NOx_analysis.lev0.nas + FR0020R.20220101000000.20230331082625.uv_abs.ozone.air.1y.1mn.FR01L_uv_abs_Teledyne_T400.FR01L_03_Teledyne_T400_GIF_ambient.lev0.nas + FR0020R.20230101000000.20240311135904.aws..met.1y.1mn.FR01L_PAL_AWS__Campbell_Scientific_TBD.FR01L_AWS_Campbell_01_ambient.lev0.nas ,precision, uncertainty, dectection limit not reported, offset corrected for NO |
| Near real time |
False |
| Uniform timeseries |
False |